3. Installation
Earthing the CPV valve terminal
All variants have an earth/ground connection for ear-
thing the CPV valve terminal. This is on both the left
and right-hand end plates (see diagram).

Fig. 3/5: Earth/ground connection of CPV valve terminal
PLEASE NOTE
Earth the CPV valve terminal.
• Connect the earth connection on the left or right-
You thereby avoid electromagnetic interference (EMC).
3-12

Earth/ground connections
hand end plate (see Fig. 2/5) with low impedance
(short cable with large cross-sectional area) to the
earth potential.