2. Fitting
Fitting variant: rear
"
!
M4 screws (CPV10/14) or M5 screws
(CPV18) for wall fitting
!
Fixing bolts (only CPV10/14)
Self-cutting screws for fastening the
"
profiles to the CPV valve terminal
Additional self-cutting screw for
CPV14/18 valve terminals
Fig. 2/2: Fitting the CPV valve terminal onto a wall
• Make sure that there is enough room to connect the
PLEASE NOTE
The boring dimensions for rear fitting of the CPV
valve terminal (Fig. 2/3) do not apply to the
CPV10/14 valve terminals with direct connection for
Interbus Loop (type CPV..-GE-IBL-..) or for AS-i con-
nection with inputs/outputs (type CPV..-GE-ASI..E/..A).
2-6
Fitting variant: front
M5.5 bore for wall fastening
Self-cutting screws for fastening the
profiles to the CPV valve terminal
power cables and the pneumatic tubing. In the case
of front fitting, a suitable spacer or cutout section
must be provided to permit access to the electrical
connections (see Fig. 2/3).
CPV... 9811d