3. Press
ENTER
This submenu contains all of the STS-3c setup parameters. You navigate
through this and all other submenus by pressing the
move an option to the selection line and then pressing the
key to choose a value for the option.

Exiting OC3port Plus Submenus

To leave a submenu, simply press the
display, or press any one of the direct access keys to begin a specific test or
perform a setup.

Connecting the OC3port Plus

Depending on the specific physical interface, the OC3port Plus is designed to be
connected to either intermediate-range, single-mode fiber systems, multi-mode
fiber optic systems, or unshielded twisted pair-155 systems. A single-mode
OC3port Plus uses fiber optic connectors located on the top of the tester.
The multi-mode version of the OC3port Plus is designed to be connected to multi-
mode fiber systems. This version uses the SC Duplex fiber-optic connectors
located on the top of the tester.
The UTP-155 version of the OC3port Plus is designed to be connected to UTP-155
networks.
2-18