Q: Driveworksez Parameters - YASKAWA U1000 Series Technical Manual

Rated output current: 200 v class: 22 to 248 a, 400 v class: 9.6 to 414 a
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

No. (Addr.)
Name
o4-02
Cumulative Operation Time
(50CH)
Selection
o4-03
Cooling Fan Operation Time
(50EH)
Setting
o4-05
Capacitor Maintenance Setting
(51DH)
o4-07
DC Bus Pre-Charge Relay
(523H)
Maintenance Setting
o4-11
U2, U3 Initialization
(510H)
o4-12
kWh Monitor Initialization
(512H)
o4-13
Number of Run Commands
(528H)
Counter Initialization
o4-19
Power Unit Price
(113AH)
 q: DriveWorksEZ Parameters
No. (Addr.)
Name
q1-01 to
q6-07
DriveWorksEZ Parameters
(1600H to
1746H)
 r: DriveWorksEZ Connection Parameters
No. (Addr.)
Name
r1-01 to
r1-40
DriveWorksEZ Connection
(1840H to
Parameters 1 to 20 (upper/lower)
1867H)
 T: Motor Tuning
Enter data into the following parameters to tune the motor and drive for optimal performance
T1: Induction Motor Auto-Tuning
No. (Addr.)
Name
T1-00
Motor 1/Motor 2 Selection
(700H)
T1-01
(701H)
Auto-Tuning Mode Selection
<37>
YASKAWA ELECTRIC SIEP C710636 03A YASKAWA U1000 Technical Manual
All Modes
0: Logs power-on time
1: Logs operation time when the drive output is active (output operation time).
All Modes
Sets the value of the fan operation time monitor U4-03 in units of 10 h.
All Modes
Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to check when the
capacitors may need to be replaced.
All Modes
Sets the value of the Maintenance Monitor for the soft charge bypass relay. See U4-06 to check
when the bypass relay may need to be replaced.
All Modes
0: U2- and U3- monitor data is not reset when the drive is initialized (A1-03).
1: U2- and U3- monitor data is reset when the drive is initialized (A1-03). (The value
of o4-11 is automatically returned to 0.)
All Modes
0: No action
1: Reset kWh data (The value of o4-12 is automatically returned to 0.)
All Modes
0: U4-02 monitor data is not reset when the drive is initialized (A1-03).
1: U4-02 monitor data is reset when the drive is initialized (A1-03). (The value of o4-13 is
automatically returned to 0.)
All Modes
Sets the energy price per 1 kWh. This parameter is used to calculate the power rate displayed for
total consumed power (U9-07 to U9-10) and total regenerated power (U9-11 to U9-14).
All Modes
Reserved for DriveWorksEZ
All Modes
DriveWorksEZ Connection Parameters 1 to 20 (upper/lower)
V/f
V/f w/PG
OLV/PM
AOLV/PM
1: Motor 1 (sets E1-, E2-)
2: Motor 2 (sets E3-, E4-)
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Rotational Auto-Tuning
2: Stationary Auto-Tuning for Line-to-Line Resistance
3: Rotational Auto-Tuning for V/f Control (necessary for Energy Savings and Speed Estimation
Speed Search)
4: Stationary Auto-Tuning 2
5: Stationary Auto-Tuning 3
8: Inertia Tuning (perform Rotational Auto-Tuning prior to Inertia Tuning)
9: ASR Gain Tuning (perform Rotational Auto-Tuning prior to ASR Gain Auto-Tuning)
Note: Inertia Tuning and ASR Gain Auto-Tuning might not be available if gears are between
the machine and the motor shaft.
Description
common_TMonly
Description
Description
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default: 0
TMonly
Min: 0
294
Max: 1
Default: 0
common_
TMonly
Min: 0
295
Max: 9999
common_
Default: 0%
TMonly
Min: 0%
295
Max: 150%
common_
Default: 0%
TMonly
Min: 0%
295
Max: 150%
common_
TMonly
Default: 0
Min: 0
295
Max: 1
common_
Default: 0
TMonly
Min: 0
295
Max: 1
common_
TMonly
Default: 0
Min: 0
296
Max: 1
Default: 000.00
Min: 000.00
296
Max: 650.00
Setting
Page
common_
Refer to Help in the
TMonly
296
DWEZ software.
Setting
Page
Default: 0
common_
TMonly
Min: 0
296
Max: FFFFH
Setting
Page
common_
Default: 1
TMonly
Min: 1
123
Max: 2
common_
TMonly
Default: 0
Min: 0
123
Max: 4, 5, 8, 9
<10>
B
453

Advertisement

Table of Contents
loading

Table of Contents