Setting 5: Air Compressor Application - YASKAWA U1000 Series Technical Manual

Rated output current: 200 v class: 22 to 248 a, 400 v class: 9.6 to 414 a
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

4.6 Application Selection
No.
b1-01
Frequency Reference Selection 1
b1-02
Run Command Selection 1
b1-03
Stopping Method Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d2-01
Frequency Reference Upper Limit
 Setting 5: Air Compressor Application
No.
A1-02
Control Method Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Drive Duty Model Selection
E1-03
V/f Pattern Selection
L2-01
Momentary Power Loss Operation Selection
No.
b1-01
Frequency Reference Selection 1
b1-02
Run Command Selection 1
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
 Setting 6: Hoist Application
Note: 1. Read the instructions listed on page
2. Perform Auto-Tuning after selecting the Hoist Application Preset.
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection 1
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Drive Duty Mode Selection
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
E1-03
V/f Pattern Selection
H2-01
Terminals M1-M2 Function Selection
H2-02
Terminals M3-M4 Function Selection
H3-06
Terminal A3 Function Selection
L2-03
Momentary Power Loss Minimum Baseblock Time
L3-04
Momentary Power Loss Voltage Recovery Ramp Time
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L8-07
Output Phase Loss Protection Selection
L8-38
Carrier Frequency Reduction Selection
L8-41
High Current Alarm Selection
<1> Max. setting value varies by the drive model selection (o2-04).
112
Table 4.13 HVAC Fan: User Parameters (A2-01 to A2-16)
Parameter Name
Table 4.14 Compressor: Parameter Settings
Parameter Name
Table 4.15 Compressor: User Parameters (A2-01 to A2-16):
Parameter Name
113
when using Hoist Application Preset
Table 4.16 Hoist: Parameters and Settings
Parameter Name
No.
d2-02
Frequency Reference Lower Limit
E1-03
V/f Pattern Selection
E1-04
Maximum Output Frequency
E2-01
Motor Rated Current
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
L2-01
Momentary Power Loss Operation Selection
o4-12
kWh Monitor Initialization
0: V/f Control
1: Reverse Prohibited
5.0 s
5.0 s
0: Heavy Duty (HD)
F: Custom V/f pattern
1: Enabled
No.
E1-03
V/f Pattern Selection
E1-07
Middle Output Frequency
E1-08
Middle Output Frequency Voltage
E2-01
Motor Rated Current
2: Open Loop Vector Control
0: Operator
3.0 Hz
0.3 s
3.0 s
3.0 s
0: Heavy Duty (HD)
2: 6.0 kHz
<1>
6.0 Hz
30.0 Hz
50. 0 Hz
F: Custom V/f pattern
5: Frequency Detection 2
37: During Frequency Output
1F: Through mode
0.3 s
0: Disabled
2.0 Hz
0.0 Hz
8: UL3, UL4 at speed agree (fault)
2%
0.5 s
1: Enabled
1: Enabled below 6 Hz
1: Enabled (alarm is output)
YASKAWA ELECTRIC SIEP C710636 03A YASKAWA U1000 Technical Manual