B.3 Parameter Table
No.(Addr.)
Name
E5-09
Motor Induction Voltage
(331H)
Constant 1 (Ke) (for PM Motors)
<3>
E5-11
Encoder Z-pulse Offset ()
(333H)
(for PM Motors)
E5-24
Motor Induction Voltage
(353H)
Constant 2 (Ke) (for PM Motors)
<3>
Polarity Switch for Initial
E5-25
Polarity Estimation
(35EH)
(for PM Motors)
<3> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting is dependent on the control mode (A1-02), the drive model (o2-04), and the Drive Duty (C6-01).
<14> Default setting value is dependent on the motor code set to E5-01.
<19> Display is in the following units.
 CIMR-U20028, 20042, and 40011 to 40027: 0.01 A units
 CIMR-U20054 to 20248, and 40034 to 40414: 0.1 A units
<28> Selection may vary depending on the motor code entered to E5-01.
 F: Option Settings
F parameters are used to program the drive for PG feedback from the motor and to function with option cards.
F1: PG Speed Control Card Settings (PG-B3/PG-F3/PG-RT3/PG-X3)
Parameters F1-01, F1-05, F1-06, F1-12, F1-13, and F1-18 through F1-21 are used to set up a PG option card plugged into
option connector CN5-C of the drive. They include "PG 1" in the parameter name.
Parameters F1-31 through F1-37 are used to set up a PG option card plugged into option connector CN5-B of the drive.
They include "PG 2" in the parameter name.
Other parameters in the F1 group are used to set operation for PG options plugged into connector CN5-C and CN5-B.
No.(Addr.)
Name
F1-01
PG 1 Pulses Per Revolution
(380H)
F1-02
Operation Selection at PG Open
(381H)
Circuit (PGo)
F1-03
Operation Selection at Overspeed
(382H)
(oS)
424
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the induced phase peak voltage in units of 0.1 mV/(rad/s) [electrical angle]. Set this
parameter when using a Yaskawa SSR1 Series PM motor with derated torque, or a Yaskawa
SST4 Series motor with constant torque.
When setting this parameter, E5-24 should be set to 0.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the offset between the rotor magnetic axis and the Z pulse of an incremental encoder. Set
during Z Pulse Offset Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the induced phase-to-phase rms voltage in units of 0.1 mV/(min
this parameter when using a Yaskawa SMRA Series SPM motor.
When setting this parameter, E5-09 should be set to 0.
V/f
V/f w/PG
OLV/PM
AOLV/PM
There is normally no need to change this parameter from the default value.
Switches polarity for initial polarity estimation.
If "Sd=1" is listed on the nameplate or in a test report for a Yaskawa motor, E5-25 should be set
to 1.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the number of PG (pulse generator or encoder) pulses.
Sets the number of pulses per motor revolution.
Note: Setting range is 0 to 15000 ppr when A1-02 = 5, 6, 7 (PM control mode).
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
4: No alarm display.
Note: Depending on the motor speed and load conditions, an error such as oC may occur.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
Note: In AOLV/PM, the motor will coast to a stop (F1-03 = 1). The setting for F1-03 cannot be
changed to 0, 2, or 3.
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
-1
) [mechanical angle]. Set
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
YASKAWA ELECTRIC SIEP C710636 03A YASKAWA U1000 Technical Manual
Setting
common_
TMonly
Default:
<14>
Min: 0.0 mV/(rad/s)
Max:
2000.0 mV/(rad/s)
common_
Default: 0.0 deg
TMonly
Min: -180 deg
Max: 180 deg
common_
Default:
<14>
TMonly
Min: 0.0 mV/(min
-1
)
Max:
6500.0 mV/(min
)
-1
common_
TMonly
Default: 0
Min: 0
Max: 1
Setting
common_
TMonly
Default:
<10>
Min: 1 ppr
Max: 60000 ppr
common_
TMonly
Default: 1
Min: 0
Max: 4
common_
TMonly
Default: 1
Min: 0
Max: 3
Page
217
217
217
217
Page
218
218
218