5.10 o: Operator Related Settings
o4-13: Number of Run Commands Counter Initialization
Resets the Run command counter displayed in U4-02.
No.
o4-13
Setting 0: No Action
The Run command data are kept as they are.
Setting 1: Number of Run Commands Counter
Resets the Run command counter. The monitor U4-02 will show 0. Once o4-13 is set to 1 and the ENTER key is pressed,
the counter value is erased and the display returns to 0.
o4-19: Power Unit Price
Sets the energy price per 1 kWh. This parameter is used to calculate the power rate displayed for total consumed power
(U9-07 to U9-10) and total regenerated power (U9-11 to U9-14).
No.
o4-19
 q: DriveWorksEZ Parameters
q1-01 to q6-07 are reserved for use with DriveWorksEZ. Refer to the DriveWorksEZ manual for more information.
 r: DriveWorksEZ Connection Parameters
r1-01 to r1-40 are reserved for use with DriveWorksEZ. Refer to the DriveWorksEZ manual for more information.
 T: Motor Tuning
Auto-Tuning automatically sets and tunes parameters required for optimal motor performance.
Refer to Auto-Tuning on page 116
296
Name
Number of Run Commands Counter Initialization
Name
Power Unit Price
for details on Auto-Tuning parameters.
Setting Range
Setting Range
0.00 to 650.00
YASKAWA ELECTRIC SIEP C710636 03A YASKAWA U1000 Technical Manual
Default
0 or 1
0
Default
000.00