B.7 Parameters That Change With The Motor Code Selection (For Pm Motors) - YASKAWA U1000 Series Technical Manual

Rated output current: 200 v class: 22 to 248 a, 400 v class: 9.6 to 414 a
Hide thumbs Also See for U1000 Series:
Table of Contents

Advertisement

B.7
Parameters that Change with the Motor Code Selection (for PM Motors)
The following tables show parameters and default settings that change with the motor code selection E5-01 when Open
Loop Vector for PM motors is used.
 YASKAWA SMRA Series SPM Motor
Table B.10 200 V, 1800 min
No.
Name
Motor Code Selection (for PM Motors)
Voltage Class
E5-01
Rated Power
Rated Speed
E5-02
Motor Rated Power (for PM Motors)
E5-03
Motor Rated Current (for PM Motors)
E5-04
Number of Motor Poles (for PM Motors)
E5-05
Motor Stator Resistance (r1) (for PM Motors)
Motor d-Axis Inductance (Ld) (for PM
E5-06
Motors)
Motor q-Axis Inductance (Lq) (for PM
E5-07
Motors)
Motor Induction Voltage Constant 1 (Ke) (for
E5-09
PM Motors)
Motor Induction Voltage Constant 2 (Ke) (for
E5-24
PM Motors)
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
C5-17
Motor Inertia
n5-02
Motor Acceleration Time
d-Axis Current for High Efficiency Control
n8-49
(for PM Motors) (OLV/PM)
Table B.11 200 V, 3600 min
No.
Name
Motor Code Selection (for PM Motors)
Voltage Class
E5-01
Rated Power
Rated Speed
E5-02
Motor Rated Power (for PM Motors)
E5-03
Motor Rated Current (for PM Motors)
E5-04
Number of Motor Poles (for PM Motors)
E5-05
Motor Stator Resistance (r1) (for PM Motors)
Motor d-Axis Inductance (Ld) (for PM
E5-06
Motors)
Motor q-Axis Inductance (Lq) (for PM
E5-07
Motors)
Motor Induction Voltage Constant 1 (Ke) (for
E5-09
PM Motors)
Motor Induction Voltage Constant 2 (Ke) (for
E5-24
PM Motors)
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
C5-17
Motor Inertia
n5-02
Motor Acceleration Time
d-Axis Current for High Efficiency Control
n8-49
(for PM Motors) (OLV/PM)
YASKAWA ELECTRIC SIEP C710636 03A YASKAWA U1000 Technical Manual

B.7 Parameters that Change with the Motor Code Selection (for PM Motors)

-1
Type YASKAWA SMRA Series SPM Motor
Unit
0002
V
200
kW
0.4
min
1800
-1
kW
0.4
A
2.1
8
2.47
mH
12.7
mH
12.7
mVs/rad
0
mV/(min
-1
)
62.0
Hz
120
V
200.0
Hz
120
Hz
6
kgm
0.0007
2
s
0.064
%
0
Type YASKAWA SMRA Series SPM Motor
-1
Unit
0103
V
200
kW
0.75
min
-1
3600
kW
0.75
A
4.1
8
0.538
mH
3.2
mH
3.2
mVs/rad
0
mV/(min
)
32.4
-1
Hz
240
V
200.0
Hz
240
Hz
12
kgm
2
0.0007
s
0.137
%
0
Default Settings
0003
0005
200
200
0.75
1.5
1800
1800
0.75
1.5
4.0
6.9
8
8
1.02
0.679
4.8
3.9
4.8
3.9
0
0
64.1
73.4
120
120
200.0
200.0
120
120
6
6
0.0014
0.0021
0.066
0.049
0
0
Default Settings
0105
0106
200
1.5
3600
3600
1.5
8.0
10.5
8
0.20
0.15
1.3
1.3
0
32.7
36.7
240
200.0
200.0
240
12
0.0014
0.0021
0.132
0.132
0
0006
0008
200
200
2.2
3.7
1800
1800
2.2
3.7
10.8
17.4
8
8
0.291
0.169
3.6
2.5
3.6
2.5
0
0
69.6
72.2
120
120
200.0
200.0
120
120
6
6
0.0032
0.0046
0.051
0.044
0
0
0108
200
200
2.2
3.7
3600
2.2
3.7
16.5
8
8
0.097
1.1
1.1
1.1
1.1
0
0
39.7
240
240
200.0
240
240
12
12
0.0032
0.122
0
0
B
473

Advertisement

Table of Contents
loading

Table of Contents