Troubleshooting

Matrix 12800 BME status information, available in the Virtualization/Control
program, as a Web page, or viewable on the FPC 5000, show the operational status
of each of the circuit boards, the power supplies, and the cooling fans in the Matrix
12800. To access the BME status via the Virtualization/Control program, click Tools
> Hardware Status. Access the BME status via an HTML page by clicking a specific
BME on the System Status page.
If a component fails, the indication turns red. On an HTML page, the airflow
indication is expressed as a percentage of the maximum airflow.

Power supplies

Symptom
One of the power
supply LEDs is not lit.
The status page
indicates that one or
more power supplies
has failed.

Cooling

Symptom
The status page
indicates reduced
airflow.
The status page
indicates that the
primary or redundant
fan pair has failed.
www.camboard.de
6-18
Matrix 12800 Switchers • Upgrades and Maintenance
CAMBOARD Electronics
Close the I/O cardcage door and turn the left and right knurled knobs ¼-turn
clockwise.
Close the front door.
If this circuit board installation is a permanent change to the size of the matrix,
the system will need to virtualized to recognize the change. Virtualize the
system using the detailed instructions in chapter 3, Virtualization/Control
Software.
If this BME does not have redundant power supplies, the switcher may or may
not shut down for an out of tolerance voltage.
The power supply modules are hot-swappable. If this BME has redundant
power supplies A and B, each power supply can be removed without powering
down the switcher. If the BME does not have power supply redundancy,
removing either primary power supply will shut down the matrix.
Cause
One of the power
supply voltages is out
of tolerance.
Cause
There is an airflow
restriction or one or
more of the fans is not
moving as much air as
expected.
One of the fans in the
fan pair has failed.
Tel. 07131 911201
Fax 07131 911203
Suggested solutions
1.
Remove and reseat the power supply.
2.
Swap this power supply with another
power supply from the BME.
3.
Replace the power supply.
Suggested solutions
1.
Clean the front panel air filter.
2.
Replace the primary and redundant fan pair
assemblies. Selectively reinstall the suspect
assemblies to determine which has failed.
1.
Replace the failed fan pair assembly.