Installation, cont'd
3
Figure 2-4 — Connecting host controller(s)
Figure 2-5 — RS-232/RS-422 port pinout
www.camboard.de
2-6
Matrix 12800 Switchers • Installation
CAMBOARD Electronics
Primary and Secondary RS-232/RS-422 ports — For systems consisting of a
single switcher or for BME 0 on a multi-BME system, connect host devices
(such as computers or touch panel control systems) or MCP 1000 remote
control panels (refer to the MCP 1000 Remote Control Panel User's Manual) to
the Primary and Secondary RS-232/RS-422 ports (figure 2-4). These 9-pin D
connectors provide for serial RS-232/RS-422 control of the matrix switcher.
Figure 2-5 shows how to wire the connectors.
Both ports are connected to both controller circuit boards; a redundant
controller is not required to use the Secondary RS-232/RS-422 port.
79
95
111
127
80
96
112
128
12
2
3
14
13
Pin
RS-232 Function
1
2
TX
5
1
3
RX
4
5
Gnd
6
9
6
Female
7
8
9
After the BMEs have been virtualized, the system can be controlled through
this connection using the PC or other host system that can generate the proper
commands.
The Matrix 12800 Switchers are factory configured for RS-232 control. To use
the switcher under RS-422 control, you must change an internal DIP switch.
See chapter 6, Upgrades and Maintenance for details.
The default communications rate is 9600 baud. Baud rates of 19.2, 38.4, and
115 are also available, see chapter 6, Upgrades and Maintenance for details.
If equipped with a redundant controller, the primary and redundant controllers
must be configured for the same communications protocol and transfer rates.
Tel. 07131 911201
Fax 07131 911203
8 0
To Primary
Host System/Device
Serial Port
To Secondary
Host System/Device
Serial Port
RS-422 Function
Not used
TX+
Transmit data (+)
Transmit data
TX-
Transmit data (-)
Receive data
RX+
Receive data (+)
Not used
RX-
Receive data (-)
Signal ground
Gnd
Signal ground
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
ce-info@camboard.de
9 6
1 1
2
1 2
8
1
6
9
5
Male
Connector