Operational reliability — The Matrix 12800 can support round-the-clock operation
Figure 1-3 — Redundant power supply backs up primary
www.camboard.de
1-6
Matrix 12800 Switchers • Introduction
CAMBOARD Electronics
in mission-critical applications, using a combination of self-diagnosis, hot-
swappable components, and optional redundant components.
Advanced computer-aided diagnostics — The Matrix 12800 performs self
diagnostics, 24 hours a day, of the I/O boards, primary and redundant power
supply voltages, controller boards, cooling status, and the overall functional
status of the matrix. The status can be monitored off-site for unmanned
applications via the Ethernet or RS-232/RS-422 communications ports.
Dual redundant, hot swappable controller boards — The primary and
redundant controller boards are internally mounted. The primary and
redundant controller boards can each initiate configuration changes or other
matrix switcher operations. Each board has an RS-232/RS-422 port for
connection of a PC or control system. Redundant controllers mean zero
downtime for the system. There will be no loss of functionality should one of
the controller boards fail. A failed controller board is easily replaceable
through the front door with no tools required. Hot swappable controllers
allow the user to replace either at any time — without powering down the
matrix.
Dual redundant, hot swappable power supplies — The internally mounted
primary and redundant power supplies are configured to automatically
switch over from a primary supply to a hot redundant supply in the case of a
failure.
The complete power circuit, from the plug, through the power supplies, to
the power's insertion onto the power distribution plane, is separate and
redundant (figure 1-3). If the installation includes uninterruptible or
completely separate power sources, the switcher will remain powered up
through any power interruption short of a simultaneous loss of power on
both power sources.
AC
Power
Primary
Redundant
Power
Power
Supply
Supply
A
A
The ready hot redundant power supplies means zero downtime for the
system and no loss of functionality should one of the primary supplies fail.
Should a primary power supply fail, the redundant power supply
immediately assumes the load of the failed primary supply. A failed power
supply is easily replaceable through the front door at any time — without
powering down the matrix, and with no tools required.