Extron IP Address field

The Extron IP Address field contains the IP address of the connected BME. This
value is encoded in the flash memory on the primary and redundant controller
circuit boards.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by
dots (periods). Each field can be numbered from 000 through 255. Leading zeroes,
up to 3 digits total per field, are optional. Values of 256 and above are invalid.
The default address is 192.168.254.254, but if this conflicts with other equipment at
your installation, you can change the IP address to any valid value.
Edit this field as follows:
1.
2.
3.
4.

Extron Name/Descriptor field

The Extron Name/Descriptor field contains the name used as the "from"
information when the Matrix 12800 e-mails notification of its failed or repaired
status. This descriptor can be changed to any valid name, up to 12 alphanumeric
characters.
Edit this field as follows:
1.
2.
3.
4.
www.camboard.de
3-24
Matrix 12800 Switchers • Virtualization/Control Software
CAMBOARD Electronics
Editing the Extron IP address while connected via the Ethernet port can
immediately disconnect the user from the Matrix 12800. Extron recommends
editing this field using the RS-232/422 link and protecting the Ethernet access
to this screen by assigning an administrator's password to qualified and
knowledgeable personnel only.
When the control program is connected to the switcher via the RS-232 link, the
administrator and user password fields are not masked. If a password has been
inadvertently changed to an unknown value, you can look up and, if desired,
change a password in this window without knowing the current password.
Click in the Extron IP Address field. The graphic cursor becomes a text
cursor.
Edit the address as desired.
Press the Tab key on the keyboard or click the mouse in another field to exit
the Extron IP Address field.
Click the Take button to make the address change take affect.
The following characters are invalid in the Extron Name/Descriptor field:
{space} ~ @ = ' [ ] { } < > ' " ; : | \ and ?.
Click in the Extron Name/Descriptor field. The graphic cursor becomes a text
cursor.
Edit the name as desired.
Press the Tab key on the keyboard or click the mouse in another field to exit
the Extron name/descriptor field.
Click the Take button to make the name change take effect.