A18 Slab props
PEP 20
Permissible prop load [kN] according to the type test
PEP 20 N 260*
L = 1.51 – 2.60 m
Outer tube
Inner tube
bottom
bottom
1.60
35.0
35.0
1.70
35.0
35.0
1.80
35.0
35.0
1.90
35.0
35.0
2.00
33.5
35.0
2.10
31.9
35.0
2.20
30.9
35.0
2.30
29.8
35.0
2.40
28.6
35.0
2.50
27.1
32.9
2.60
24.8
29.4
2.70
2.80
2.90
3.00
3.10
3.20
3.30
3.40
3.50
3.60
3.70
3.80
3.90
4.00
4.10
4.20
4.30
4.40
4.50
4.60
4.70
4.80
4.90
5.00
All PEP 20 Props correspond to Class D
of DIN EN 1065, i. e. the permissible
load for all extension lengths is a mini-
mum of 20 kN.
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
PEP 20-300
L = 1.71 – 3.00 m
L = 1.96 – 3.50 m
Outer tube
Inner tube
Outer tube
bottom
bottom
bottom
36.4
36.4
36.4
36.4
36.1
36.4
36.4
33.2
36.4
36.4
31.4
36.4
36.4
29.9
36.4
36.4
28.7
36.4
36.4
27.7
36.4
36.4
26.9
36.3
34.8
25.7
32.7
33.4
24.0
29.3
32.1
22.3
26.5
31.1
20.5
23.9
30.1
28.3
26.5
24.8
23.1
21.3
When using PERI Slab Tables, the
permissible load for all PEP 20 Props
is a minimum of 30 kN over the entire
extension lengths due to the clamping
in the Table Swivel Head or UNIPORTAL
Head.
PEP 20-350
PEP 20-400
L = 2.21 – 4.00 m
Inner tube
Outer tube
bottom
bottom
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
35.7
34.6
32.5
33.5
29.7
32.1
27.2
30.5
24.8
28.7
26.9
25.3
23.7
22.3
20.7
*For the N Props, a use of the inner
tube at the bottom is only possible in
connection with PERI Slab Tables or
SKYDECK (bolted head).
PEP 20-500
L = 2.71 – 5.00 m
Inner tube
Outer tube
Inner tube
bottom
bottom
bottom
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
36.4
34.9
36.4
36.4
32.1
36.4
36.4
29.8
36.4
36.4
27.6
36.4
36.4
25.5
36.4
36.4
23.5
35.3
36.4
33.3
36.4
31.5
36.4
29.8
35.0
28.2
32.9
26.8
30.8
25.3
28.9
24.1
27.2
22.8
25.7
21.5
24.1
20.3
22.1