Delta ASDA-A2 Series User Manual page 480

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P5-67
POV7
Operation
Interface:
Default: 800.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the eighth
position.
P5-68
POV8
Operation
Interface:
Default: 1000.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Display
Format:
Input Value
Example:
Settings:
In PR mode, this parameter is used to set the moving speed for the ninth
position.
Revision September 2012
Moving Speed Setting of Position 7
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Moving Speed Setting of Position 8
Keypad / Software
PR
Unit: 1 r/min
Decimal
1 = 1 r/min
Chapter 8 Servo Parameters
Communication
8000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Communication
10000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Address: 0586H
0587H
Related Section:
Section 7.10
Address: 0588H
0589H
Related Section:
Section 7.10