Delta ASDA-A2 Series User Manual page 430

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

A2
ASDA-
P3-02
PTL
Operation
Interface:
Default: 6
Control
Mode:
Range: 0 ~ 8
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set the communication protocol. The alphanumeric
characters represent the following: 7 or 8 is the number of data bits; N, E or O
refers to the parity bit, Non, Even or Odd; the 1 or 2 is the numbers of stop bits.
0: Modbus ASCII mode, <7,N,2>
1: Modbus ASCII mode, <7,E,1>
2: Modbus ASCII mode, <7,O,1>
3: Modbus ASCII mode, <8,N,2>
4: Modbus ASCII mode, <8,E,1>
5: Modbus ASCII mode, <8,O,1>
6: Modbus RTU mode, <8,N,2>
7: Modbus RTU mode, <8,E,1>
8: Modbus RTU mode, <8,O,1>
P3-03
FLT
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to determine the operating sequence once a
communication fault has been detected. If '1' is selected, the drive will stop
operating upon detection the communication fault. The mode of stopping is set
by parameter P1-32.
Revision September 2012
Communication Protocol
Keypad / Software
ALL
Unit: N/A
Hexadecimal
Transmission Fault Treatment
Keypad / Software
ALL
Unit: N/A
Hexadecimal
Chapter 8 Servo Parameters
Communication
Communication
Address: 0304H
0305H
Related Section:
Section 9.2
Address: 0306H
0307H
Related Section:
Section 9.2
8-153