The parameters P2-23 and P2-24 are the first group of notch filter parameters
and the parameters P2-43 and P2-44 are the second group of notch filter
parameters.
P2-43
NCF2
Operation
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set second resonance frequency of mechanical system.
It can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-44 is set to 0, this parameter is disabled.
The parameters P2-23 and P2-24 are the first group of notch filter parameters
and the parameters P2-43 and P2-44 are the second group of notch filter
parameters.
P2-44
DPH2
Operation
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-43. If P2-44 is set to 0, the parameters P2-43 and P2-44 are
both disabled.
Revision September 2012
Notch Filter 2 (Resonance Suppression)
Keypad/Software
ALL
Unit: Hz
Decimal
Notch Filter Attenuation Rate 2
(Resonance Suppression)
Keypad/Software
ALL
Unit: dB
Decimal
Chapter 6 Control Modes of Operation
Communication
Communication
Address: 0256H
0257H
Related Section:
Section 6.3.7
Address: 0258H
0259H
Related Section:
Section 6.3.7