A2
ASDA-
P0-12★
CM4
Operation
Interface:
Default: -
Control
Range: -
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to provide the value of one of the status monitoring
functions found in P0-02. Please refer to section 7.2.1 Monitoring Variables.
The value of P0-12 is determined by P0-20 (desired drive status) through
communication setting or the keypad. The drive status can be read from the
communication address of this parameter via communication port.
When reading the drive status through the keypad, if P0-02 is set to 26, VAR-4
will quickly show for about two seconds and then the value of P0-12 will display
on the display.
P0-13★
CM5
Operation
Interface:
Default: -
Control
Range: -
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to provide the value of one of the status monitoring
functions found in P0-02. Please refer to section 7.2.1 Monitoring Variables.
The value of P0-12 is determined by P0-20 (desired drive status) through
communication setting or the keypad. The drive status can be read from the
communication address of this parameter via communication port.
Revision September 2012
Status Monitor 4
Keypad/Software
ALL
Mode:
Unit: -
Decimal
Status Monitor 5
Keypad/Software
ALL
Mode:
Unit: -
Decimal
Chapter 8 Servo Parameters
Communication
Communication
Address: 0018H
0019H
Related Section:
Section 4.3.5
Address: 001AH
001BH
Related Section:
Section 4.3.5
8-41