Chapter 8 Servo Parameters
P2-74
ALDY
Operation
Interface:
Default: 0.000
Control
Range: -25.000 ~ +25.000, with 3 fraction digits
Data Size: 16-bit
Display
Format:
Settings:
(This function is available in firmware version V1.038 sub26 and later models only)
This parameter is used to set for the compensation of delay time from digital
input.
P2-75
ALTG
Operation
Interface:
Default: 0
Control
Range: 0 ~ (P5-84 /P5-83)-1
Data Size: 32-bit
Display
Format:
Settings:
(This function is available in firmware version V1.038 sub26 and later models only)
Note:When the input value is over the setting range, an error will occur and
display on LCD display. Then, the user cannot input the setting value.
Note:When a correct value is already set in P2-75 and does not exceed the
setting range, if a change on P5-84 or P5-83 cause the value to exceed the
setting range, this parameter will be reset to 0 automatically.
New value of P2-75 = 0 if P2-75 >=(P5-84 /P5-83)
8-146
E-Cam Alignment - DI Delay Time
Compensation
Keypad/Software
PR
Mode:
Unit: ms with fraction down to usec
Decimal
E-Cam Alignment - Alignment Target
Position
Keypad/Software
PR
Mode:
Unit: The pulse unit of Master axis
Decimal
Communication
Communication
ASDA-
Address: 0294H
0295H
Related Section: N/A
Address: 0296H
0297H
Related Section: N/A