4. Replacement and Adjustment
PCBs, HDD
Before You Begin
Board Locations
The number of boards has been reduced for the machines of this series. These boards have been
eliminated:
• IPU (Functions moved to the BICU)
• CTL PSU (Controller PSU)
• CNB
• DRB
• PFB
These boards were not in the previous machines:
• RYB (Relay Board)
• AC drive board
• DHB
Inside the Controller Box
[1]
BICU
[2]
Controller board
[3]
HDD
• The BCU of the previous machines has been renamed "BICU" for these machines.
• In the previous machines the BCU was behind the controller box.