10. Lift the vertical guide to disconnect it, and then pull it out of the machine.
Tray 1 PFU
• This procedure is for Tray 1 only. If you are servicing Tray 2 or Tray 3, just go to the next section
below.
There is a guide plate above the PFU of Tray 1 that must be removed before you can remove the Tray 1
PFU.
1. At the front [A] remove the guide plate screw.
2. Swing the front of the plate [B] slightly to the right.