4. Replacement and Adjustment
6. Turn the bracket over, and disconnect the LED PCB.
7. Separate the bracket and LED PCB.
8. Lay the LED PCB flat with the LEDs facing up.
Reassembly
1. Inspect replacement Exposure LEDs for dust or other particles and clean with a blower brush before
installation.
• Handle Exposure LEDs with care. Never touch the LED window [A] or LEDs [B] with bare
hands.