Development Unit
• The toner pan must be cleaned at every PM interval (300 K).
12. Separate the bottom plate so you can see the motor [A].
13. Disconnect motor bracket [B]
14. Remove the motor bracket with motor attached [A], and then lay it on a flat, clean surface.
15. Disconnect motor bracket [B].
655