Advertisement

5. Computer Remote Control
Suspending CRC Mode
Halting CRC
Operations
5-4
CRC Mode can be suspended temporarily to allow you to go into
terminal mode to view or change parameter settings or the device data in
memory. If the User Menu Port is set to T (Terminal port) press
S
+Z + E
to suspend CRC Mode. If you are controlling the
HIFT
NTER
programmer from the Remote port, send the 49] command.
To halt any command or any ongoing CRC operation, use one of the
following commands from the Remote port. Neither of the following two
commands requires an E
terminate any preceding command operation.
ASCII
Command Hex Code
E
1B
SC
B
n/a
REAK
. Both commands are immediate and both
NTER
Description
Causes the programmer to unconditionally
halt any operation except a binary transfer.
Causes the programmer to unconditionally
halt any operation in progress. This includes
all data communications transfers. The data
line must be held in the spacing condition for
110 ms to 700 ms.