Operation

7.2 Switching on and switching off

NOTICE
Motor damage caused by uneven running or abnormal noise
The servo geared motor can be damaged by improper handling during transport, storage or
installation. If a damaged servo geared motor is operated, this can damage the winding or
bearings and could even destroy the system.
• In case of uneven running or abnormal noise, switch off the servo geared motor.
• Identify the cause.
7.2
Switching on and switching off
Note
EMERGENCY OFF
To avoid accidents, inform yourself about the EMERGENCY OFF function before you switch
on the system.
The motor is switched on and off using the frequency converter.
● For more information on this topic, see the chapter in the Operating Instructions for the
converter.
Switching on
Precondition
● Ensure that the frequency converter is correctly parameterized.
● Check whether sufficient heat is dissipated from the motor.
Procedure
1. Switch on the motor at the frequency converter.
2. Observe any uneven running and abnormal noise of the motor.
3. Check the function of the safety equipment.
4. Check whether the motor reaches the required parameters
You have switched on the motor.
Switching off
● Switch off the motor at the frequency converter.
132