At installation altitudes of 2000 m above sea level or higher, the voltage stress on the motors
must be reduced accordingly based on the "Factors for reducing the maximum DC-link
voltage" table (reciprocal values from EN 60664-1 Table A. 2).
Table 2- 3
Installation altitude up to m above mean sea level
As the DC-link voltage is reduced, the converter output voltage also decreases.
Operation in a vacuum is not permissible because of the low dielectric strength and poor
heat dissipation.
2.4

Structure of the article number

The following overview describes the structure of the article number.
The article number comprises a combination of digits and letters. You can find possible
combinations in the Catalog D41
(https://support.industry.siemens.com/cs/document/109747093/catalog-d-41%3A-simotics-s-
1fg1-servo-geared-motors-helical-parallel-shaft-bevel-and-helical-worm-geared-
motors?dti=0&lc=en-US).
Note
Note that not every theoretical combination is possible in practice.
SIMOTICS S-1FG1 servo geared motor
Operating Instructions, 07/2019, A5E47360747B AA
Factors for reducing the maximum DC-link voltage
2000
3000
4000
5000
6000
7000
8000
Description
2.4 Structure of the article number
Factor
1
0.877
0.775
0.656
0.588
0.513
0.444