Description

Overview
The SIMOTICS S-1FG1 servo geared motor forms a single system comprising a mechanical
gearbox and a compact, permanent-magnet synchronous motor. The available options,
gearbox variants and encoders, together with the expanded product range, mean that the
1FG1 servo geared motors can be optimally adapted to any application. They therefore also
satisfy the permanently increasing demands of state-of-the-art machine generations.
The servo geared motor can be combined with the SINAMICS S120 drive system to create a
high-performance system with a high degree of functionality. The integrated encoder
systems for speed and position control can be selected depending on the application.
The servo geared motors are designed for operation without external cooling and the heat is
dissipated through the motor surface. The 1FG1 servo geared motors have a high overload
capability.
2.1

Use for intended purpose

Motors not used for the intended purpose
If you do not use the motors correctly, there is a risk of death, severe injury and/or material
damage.
• Only use the motors for their intended purpose.
• Make sure that the conditions at the location of use comply with all the rating plate data.
• Make sure that the conditions at the location of use comply with the conditions specified
Malfunctions of active implants due to magnetic and electrical fields
Electric motors endanger people with active implants, for example heart pacemakers, who
come close to the motors.
• If you are affected, stay a minimum distance of 300 mm from the motors (tripping
SIMOTICS S-1FG1 servo geared motor
Operating Instructions, 07/2019, A5E47360747B AA
WARNING
in this documentation. When necessary, take into account deviations regarding
approvals or country-specific regulations.
WARNING
threshold for static magnetic fields of 0.5 mT according to Directive 2013/35/EU).