8.5

Decommissioning the machine

NOTICE
Damage as a result of an extended period out of service
If the machine is going to be out of service for longer than six months, then take the necessary
measures for preservation and storing. Otherwise damage to the machine will result.
Record the decommissioning steps. This log will be useful upon recommissioning.
8.6

Switch off the external fan

Do not immediately switch off the separately-driven (external) fan after switching off the
machine. First wait for the machine to cool down. This will prevent the accumulation of residual
heat.
8.7

Re-commissioning the machine

When you re-commission the machine, proceed as follows:
● Study the record made when the machine was decommissioned, and reverse the measures
● Perform the measures listed in the "Commissioning" section.
See also
Start-up (Page 91)
8.8

Switching on again after an emergency switching-off

● Check the machine before recommissioning the driven machine after an Emergency Off.
● Eliminate all the causes that have led to the emergency off
SIMOTICS FD 1LQ1
Operating Instructions 01/2019
that were taken for conservation and storage.