Mnemonic
Name
Command
RZ
RF On/Off Pin
Polarity
SC
Set
Configuration
Priority
62
Quasonix, Inc.
Description
Set or show the polarity of the RF
On/Off pin, which is pulled high
internally to 3.3 VDC
RZ 0 means the RF is ON when
the RF On/Off pin is low
RZ 1 means the RF is ON when
the RF On/Off pin is high
(floating)
Examples:
RZ
Show the current RF
On/Off polarity
RZ 0
Set RF On/Off polarity to
"pin low = on"
RZ 1
Set RF On/Off polarity to
"pin high = on"
The default polarity on most
Quasonix transmitters is high.
The RF On/Off pin is a hard OFF
control. No matter what state
everything else is in, setting this
switch input to the inactive state
will turn RF Off.
Set or show current configuration
priority setting.
Valid settings are:
0 – Ignore frequency plug on
power up; use NV stored settings
1 – Ignore stored setting; read
frequency plug on power up
2 – Ignore frequency plug
(always)
3 – Ignore serial port frequency
command (always)
4 – Ignore frequency plug on
power up; enable debugs
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Setting
Required
Saved?
Standard
Y
PF or PM
Y
Factory
Default
RZ 1