Mnemonic
Name
Command
]
Active Channel
Frequency Step
Up
, (comma)
Active Channel
Step Down
Power
. (period)
Active Channel
Step Up Power
/
Current Settings
AC
Automatic
Carrier Output
35
Quasonix, Inc.
Description
Right square bracket key retunes
the transmitter to the next higher
active channel frequency, as
determined by the frequency step
(FS) parameter
Reply to the control window is the
new frequency, in MHz
No Enter key required
Incrementally steps down the
active channel output power level,
from 31 down to 0
One step per key press
No Enter key required
Incrementally steps up the active
channel output power level, from
0 up to 31
One step per key press
No Enter key required
Quickly displays the current dual
transmitter settings
Report or set automatic carrier
output state
With automatic carrier ON (AC 1),
the unit will output an
unmodulated, on-frequency
carrier if there is no clock present.
When automatic carrier is OFF
(AC 0), the RF output will be
muted in the absence of clock.
Note that the AI, CF, and CS
commands can create a clock,
even when one is not externally
applied.
Examples:
AC
Report the automatic
carrier state
AC 0
Set automatic carrier OFF
AC 1
Set automatic carrier ON
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Setting
Required
Saved?
Standard
N/A
VP
N/A
VP
N/A
Standard
N/A
AC
N
ACS
Factory
Default
N/A
N/A
N/A
N/A
AC 1
Need help?