Quasonix TIMTER Installation And Operation Manual page 60

Multi-mode dual telemetry transmitter
Hide thumbs Also See for TIMTER:
Table of Contents

Advertisement

Mnemonic
Name
Command
MA
Modes Allowed
MJ
Modulation
Scaling Step
Size
53
Quasonix, Inc.
Description
Reports the modes (modulations)
enabled on the transmitter, as
determined by the part number
Example:
MA
Show available modes
0
- PCMFM
1
- SOQPSK
2
- MHCPM
3
- BPSK
4
- QPSK
5
- AQPSK
6
- Carrier Only
7
- OQPSK
8
- UQPSK
9
- AUQPSK
13 – STC
14 – DPM
Sets the current modulation
scaling factor used when the
single key Power Step Up and
Power Step Down functions are
used
Valid range is .0009 to 10.01
Examples:
MJ
Report the current scaling
factor
MJ 5
Set the scaling factor to 5
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Setting
Required
Saved?
Standard
N/A
MS
Y
Factory
Default
N/A
MJ 1.5