Mnemonic
Name
Command
QA
Query All
QC
Internal Clock
Rate
QD
Internal Q Data
Pattern
QT or TE
Query
Temperature
RA or RN
Randomizer
59
Quasonix, Inc.
Description
Displays common device settings
in one compact display
Display is a subset of SS or ST
Sets the internal Q clock rate, in
MHz, to be used if the clock
source is set to internal
Value is rate in Mbps (or freq in
MHz)
Examples:
QC
Show internal Q clock
rate
QC 10 Set internal Q clock rate
to 10 MHz
Sets the internal data pattern to
either a pseudorandom bit pattern
(PN 6, 11, 15, and 23 are
currently supported) or to a fixed
16 bit word pattern. (Currently
independent mode not available;
If independent I and Q data is
enabled with the IQ command,
then this sets the Q data pattern.)
Examples:
QD
Report the current
internal data pattern
QD PN15
Set pattern to
PN15
QD USER 5555 16
pattern to 16 bit pattern of 5555h
or bin 0101010101010101
Report the temperature in
degrees Celsius
Report or set randomizer state
Examples:
RA
Report the randomizer
state
RA 0
Set randomizer OFF
RA 1
Set IRIG-106 randomizer
ON
RA 2
Set CCSDS randomizer
ON
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Required
Standard
Standard
Standard
Set
Standard
Standard
RA 2
requires
LD6 option
and LDPC
enabled
Setting
Factory
Saved?
Default
N/A
N/A
N/A
N/A
Y
RA 0