Mnemonic
Name
Command
PF
PSK Filter Select
PL
Power Level
PR or RE
Restore Defaults
PSTP
Power Level
Step
58
Quasonix, Inc.
Description
Sets or shows the current PSK
filter selection This is valid if the
PSK mode option is enabled and
for any *PSK (legacy) modes
AND for DPM (no option required)
if that mode exists on the
transmitter.
Valid filter range is 0 to 255
Examples:
PF
Show current PSK filter
PF 42 Set PSK filter to 42
This is a read only command;
PL reports the current power level
setting for the dual power feature
Examples:
PL
Report the current power
level state
Disabled in Parallel Mode
Restores factory default
parameters for the unit
Default is currently the lowest
number modulation supported by
the transmitter with the selected
band and frequency limits
Default power level is Full power
Sets the power level step, in dB,
to be used when the power
stepping commands are issued to
step the power up or down for a
channel
Valid stepping commands are >
< . and , (greater/less than
symbols, period, and comma)
Examples:
PSTP Show current power level
step size
PSTP 1 Set power level step to 1
dB
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Setting
Required
Saved?
All *PSK
Y
DP
Y
Standard
N/A
Standard
N/A
Factory
Default
PF 255
(PF 10 if
DPM)
PL 0
N/A
N/A