Installing the Switch in an Equipment Rack with AT-RKMT-J14
Brackets

Required Items

Switch
Orientations in
the Equipment
Rack
This section contains the procedure for installing XS900MX Switches in a
standard 19-inch equipment rack, with the AT-RKMT-J14 Brackets
included with the units.
The following items are required to install the switch in an equipment rack
with the AT-RKMT-J14 Brackets:
Two AT-RKMT-J14 equipment rack brackets (included with the
switch)
Eight M4x6mm bracket screws (included with the switch)
Four M3x6mm screws (included with the switch)
Two bracket handles (included with the switch)
Cross-head screwdriver (not provided)
Four standard equipment rack screws (not provided)
The switch has two sets of four screw holes on the left and right sides, for
attaching the AT-RKMT-J14 Brackets. Refer to Figure 23.
Figure 23. Bracket Holes for AT-RKMT-J14 Brackets
XS900MX Series Installation Guide for VCStack
Bracket Holes
Bracket Holes
59