Verifying The Member Switch; Table 11: Verifying The Member Switch - Allied Telesis XS900MX Series Installation Manual

Stackable 10gigabit ethernet switches alliedware plus version 5.4.8. for vcstack.
Hide thumbs Also See for XS900MX Series:
Table of Contents

Advertisement

Table 10. Configuring the Member Switch - Part II (Continued)
Step
12
Designate the ports as the trunk with the STACKPORT command.
awplus(config-if)# stackport
% Save the config and restart the system for this change to take
effect.
Steps 13 to 18 save your changes and reboot the switch.
13
Return to the Global Configuration mode.
awplus(config-if)# exit
14
Return to the Privileged Exec mode.
awplus(config)# exit
15
Save your changes with the WRITE command.
awplus# write
Building configuration ...
[OK]
16
Restart the switch.
awplus# reboot
reboot system? (y/n):
17
Type "Y" for yes.
18
Wait two minutes for the switch to initialize its management software.
19
Go to "Verifying the Member Switch," next.
Verifying the
Member Switch
Step
1
Start a local management session. Refer to "Starting a Local Management Session" on
page 86.
2
Move to the Privileged Exec mode.
awplus> enable
Description and Command
Perform the steps in Table 11 to confirm the configuration of the member
switch.
Table 11. Verifying the Member Switch
Description and Command
XS900MX Series Installation Guide for VCStack
123