Installing The X530L-10Ghxm Switch In An Equipment Rack With The Rkmt-J14 Brackets; Required Items; Switch Orientations In The Equipment Rack - Allied Telesis x530L Series Installation Manual

Stackable gigabit layer 3+ ethernet switches
Hide thumbs Also See for x530L Series:
Table of Contents

Advertisement

Chapter 5: Installing the Switch in an Equipment Rack
Installing the x530L-10GHXm Switch in an Equipment Rack with the
RKMT-J14 Brackets

Required Items

Switch
Orientations in
the Equipment
Rack
110
This section contains the procedure for installing the x530L-10GHXm
Switch in a standard 19-inch equipment rack, with the RKMT-J14 Brackets
included with the switch.
The following items are required to install the switch in an equipment rack
with the RKMT-J14 Brackets:
Two RKMT-J14 equipment rack brackets (included with the switch)
Eight M4x6mm bracket screws (included with the switch)
Four M3x6mm screws (included with the switch)
Two bracket handles (included with the switch)
Cross-head screwdriver (not provided)
Four standard equipment rack screws (not provided)
The switch has two sets of four screw holes on the left and right sides, for
attaching the RKMT-J14 Brackets. Refer to Figure 49.
The brackets also have two sets of four holes. Refer to Figure 50 on page
111.
Bracket Holes
Figure 49. Bracket Holes