Specifi Cations - Valor H6 Series Installation And Owner's Manual

Direct vent zero clearance gas fireplaces
Hide thumbs Also See for H6 Series:
Table of Contents

Advertisement

Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the Natural Gas and Propane
Installation Code CAN/CGA-B149.1. Only qualifi ed
licensed or trained personnel should install this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1400KN is used with natural gas.
Heater engine 1400KP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section.
Specifi cations
The supply connection is 3/8"
NPT male and located on the
right hand side of the fi rebox.
A shut-off valve (not supplied)
is required on the supply line to
isolate the unit during service.
See Supply Gas Installation
section for details.
Conversion Kits
The 1400K is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kits for further information.
Electrical
The 1400K is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate optional 1195CFK Circulating Fan Kit, 1270RBK
Remote Blower Kit or GV60PAK Power Adapter.
1400KN 1400KP
LDK HeatShift Duct Kit
Natural
Propane
The 1400K is designed to allow the installation of the
0-4,500 feet*
optional LDK HeatShift Duct Kit, a convection system
36,000
36,000
that redistributes the warm air fl ow away from the
19,000
15,000
fi replace opening to a more desirable location using
4.0"
9.5"
natural convection, without use of a fan.
5.0"
11.0
The warm air fl ow may be relocated to a position higher
10.0"
14.0
up the wall, out the sidewalls, or even to another room.
DMS#32
DMS#49
The result is much cooler wall temperatures above the
51
30
fi replace opening for locating televisions, artwork, etc.
220
125
Please note that the framing and mantel clearances
are aff ected by the installation of the LDK. Refer
to the installation manual packed with the kit for more
information.
Outdoor Conversion Kit
The 1400K models are supplied standard for indoor
applications and may be adapted for installation in
specifi c "outdoor" applications protected from weather as
defi ned in the GV60CKO outdoor conversion kit manual.
WARNING
!
O p t i o n a l e l e c t r i c a l a c c e s s o r i e s
A R E N O T A L L O W E D w h e n a d a p t i n g
a p p l i a n c e f o r o u t d o o r u s e .
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.
QUALIFIED
INSTALLER
X
19