Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in
w.c.)
Minimum Supply
Pressure (in w.c.)
Maximum Supply
Pressure (in w.c.)
Main Burner Injector
Marking
Pilot Injector Marking
Min. Rate By-Pass
Screw
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
20
Specifi cations
N
P
Natural
Propane
0-4,500 feet*
42,000
42,000
23,000
23,000
3.5"
10"
5"
11"
10"
14"
1400
420
51
30
260
160
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1800JN is used with natural gas.
Heater engine 1800JP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
X
The supply connection is 3/8" NPT male and located
on the left hand side of the fi rebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
unit during service. See Supply Gas Installation section
for details.
Conversion Kits
The 1800J L3 is supplied as natural gas or propane
gas and is fi eld convertible between fuels. See
instructions packaged with the conversion kit for further
information.
Electrical
The 1800J is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power
to operate optional 1595CFK Circulating Fan Kit or
1270RBK Remote Blower Kit.
LDK Duct Kit
The 1800J is designed to allow the installation of
the optional LDK Duct Kit, a convection system that
redistributes the warm air fl ow away from the fi replace
opening to a more desirable location using natural
convection, without use of a fan.
The warm air fl ow may be relocated to a position higher
up the wall, out the sidewalls, or even to another room.
The result is much cooler wall temperatures above the
fi replace opening for locating televisions, artwork, etc.
Please note that the framing and mantel clearances
are affected by the installation of the LDK. Refer
to the installation manual packed with the kit for more
information.