Check Operation; Adjust Aeration If Needed - Valor H6 Series Installation And Owner's Manual

Direct vent zero clearance gas fireplaces
Hide thumbs Also See for H6 Series:
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Check Operation

Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions starting on page 8.

Adjust Aeration if needed

Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. The burner is
equipped with an adjustable shutter to control primary
aeration. The shutter is factory-set to an aeration gap
which will give optimum performance for the vast
majority of installations.
Depending of the fuel bed used, altitude and other
considerations, the fl ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed, panels and window installed and evaluating
the fl ame picture after a 15-minute warm-up.
Open
66
Installation
Air shutter
Air shutter
slider
Wing nut
Aeration
under lever
lever
Close
Increasing aeration will cause the fl ames to appear
more transparent and blue showing more ceramic
eff ects glow.
Decreasing aeration will cause the fl ames to appear
more yellow or orange showing less ceramic eff ects glow.
Too little aeration may result in black carbon forming
on logs or roof panel and dropping into the fi rebox.
Air Shutter
The air shutter is located at the back of the burner. It is
linked to a lever located under the fi rebox. To adjust the
air shutter:
1. Locate the aeration lever and the wing nut under the
fi rebox left of the valve.
2. Loosen the lever's wing nut. Do not remove the
wing nut!
3. Move the lever left or right to the desired position.
4. Tighten the wing nut.