Specifi Cations - Valor 1100JN Installation & Owner's Manual

H5 series, direct vent zero clearance gas fireplaces, natural/propane gas
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the Natural Gas and Propane
Installation Code CAN/CGA-B149.1. Only qualifi ed
licensed or trained personnel should install this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
Input ratings are shown in BTU per hour and are certifi ed
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current ANSI
Z223.1 and/or local codes having jurisdiction. Heating
value of gas in some areas is reduced to compensate for
elevation—consult your local gas utility to confi rm.
For installations at elevations above 4,500 feet (1,370 m)
in Canada, please consult provincial and/or local
authorities having jurisdiction.
Supply Gas
Heater engines 1100JN and 1150JLN are used with
natural gas.
Heater engines 1100JP and 1150JLP are used with
propane gas.
The supply pressure must be between the limits shown in
the Ratings section.
22
Specifi cations
.
1100JN
1100JP
1150JLN 1150JLP
Natural
Propane
Natural
0-4,500 feet**
28,000
28,000
30,000
13,000
13,000
16,000
3.5"
9"
5"
11"
10"
14"
10"
850
300
850
51
30
51
185
125
195
The supply connection is 3/8"
NPT male and located on the right
hand side of the fi rebox. A shut-off
valve (not supplied) is required on
the supply line to isolate the unit
during service. See Supply Gas
Installation section for details.
Conversion Kits
The 1100J and 1150J are supplied as natural gas or
propane gas and are fi eld convertible between fuels. See
instructions packaged with the conversion kits for further
information.
Electrical
The 1100J and 1150J are designed to run on battery power
and do not require an electrical power source to operate as
a heater. However, they require electrical power to operate
optional 1195CFK Circulating Fan Kit, 1270RBK Remote
Blower Kit or GV60PAK Power Adapter.
LDK HeatShift Duct Kit
The 1100J and 1150J are designed to
Propane
allow the installation of the optional LDK
HeatShift Duct Kit, a convection system
30,000
that redistributes the warm air fl ow away
from the fi replace opening to a more
16,000
desirable location using natural convection,
4"
9"
without use of a fan.
5"
11"
The warm air fl ow may be relocated to
a position higher up the wall, out the
14"
sidewalls, or even to another room. The
result is much cooler wall temperatures
360
above the fi replace opening for locating
30
televisions, artwork, etc.
135
Please note that the framing and
mantel clearances are aff ected by the
installation of the LDK. Refer to the
installation manual packed with the kit for
more information.
Outdoor Conversion Kit
The 1100J-1150J models are supplied standard for indoor
applications and may be adapted for installation in specifi c
"outdoor" applications protected from weather as defi ned
in the GV60CKO outdoor conversion kit manual.
!
O p t i o n a l e l e c t r i c a l a c c e s s o r i e s
A R E N O T A L L O W E D w h e n a d a p t i n g
a p p l i a n c e f o r o u t d o o r u s e .
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.
WARNING