Install Appliance with 1430 Fixed Framing Kit
Part of the 1430 Fixed Framing Kit installs at the time
of framing the appliance.
The side brackets provided loose with the appliance
are not needed with this kit.
The 1430 Fixed Framing Kit is not compatible with
any other trim or door kits.
Hearth considerations
You need to know whether there will be a hearth or
not in front of the appliance and some rules must be
considered:
Without hearth (up the wall)
In the case where there is no hearth, the bottom
of the appliance must be raised at least 4" inches
above any combustible fl oor in front.
With hearth
Only a non-combustible hearth can be installed
in front of the appliance if within 4" vertically
of the bottom of the appliance. See Hearth
Requirements section of this manual.
The non-combustible hearth in front of the
appliance, if within 4" of the bottom of the
appliance, must include the 1/2" Micore insulation
board provided to be used as thermal break
between non-combustible and combustible
material underneath.
Non-combustible
material
1/2" combustible
shim at ends to
match Micore
Finishing with hearth
44
Installation
Removable panel
Lower panel
1/2" insulating Micore panel
(supplied with appliance)
Front of
appliance
1-1/8"
(29 mm)
Section view, up the wall—detail
Removable panel
Finishing up the wall
Front of
appliance
1-1/2" (38 mm)
Appliance base
Plywood
Section view, hearth—detail
sub-floor
1-1/2" (38 mm)
max. thickness
(including Micore)
Removable panel
Lower panel
Appliance base
Plywood base
Stud
Appliance base
Lower panel
Plywood
base
Stud
Removable panel
Lower panel
Appliance base
Plywood