Specifi Cations - Valor LX2 Series Installation & Owner's Manual

Direct vent zero clearance corner gas fireplaces
Hide thumbs Also See for LX2 Series:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the Natural Gas and Propane
Installation Code CAN/CGA-B149.1. Only qualifi ed
licensed or trained personnel should install this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
24
SPECIFICATIONS
JN
JP
Natural
Propane
0-4,500 feet*
36,000
36,000
19,000
21,000
4.0"
9.5"
5"
11"
10"
14"
DMS#32 DMS#49
51
30
220
160
Supply Gas
Heater engines
2200LJN/2200RJN are
used with natural gas.
Heater engines
2200LJP/2200RJP are
used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 1/2" NPT male and located
on the rear left side of the fi rebox. A shut-off valve
(supplied) is required on the supply line to isolate the
unit during service. See Supply Gas Installation section
for details.
Conversion Kits
The 2200J LX2 is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kit for further information.
Electrical
The 2200J is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate the interior lighting, the optional 2200ULK
Underbed Lighting Kit or 1270RBK Remote Blower Kit.
LDK HeatShift Duct Kit
The 2200 MUST be installed with the LDK
HeatShift Duct Kit , a convection system that
redistributes the warm air fl ow away from the fi replace
opening to a more desirable location using natural
convection, without use of a fan.
The warm air fl ow may be relocated to a position higher
up the wall, out the sidewalls, or even to another room.
The result is much cooler wall temperatures above the
fi replace opening for locating televisions, artwork, etc.
Refer to the installation manual packed with the kit for
more information.
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.