Setting P2 ON and OFF times.
Repeat same steps as Setting P1 ON and OFF times.
When all settings are complete, press
Timer Programming Example (default temperatures shown)
6:00 am
Start time
P1
Set temp
74 F
Automatic Turn Down
6 Hour no Motor Movement
Manual Mode/Temperature/Timer Mode: The valve will
turn to pilot ame if there is no change in ame height
for a 6 hour period. In Temperature/Timer Mode if the
ambient room temperature changes, the ame height
will adjust automatically to maintain set temperature,
and the re will continue to function normally. The
valve will turn to pilot ame if the set temperature and
the ambient room temperature remain the same over a
6 hour period.
Automatic Shut-O
Low batteries receiver.
With low battery power
in the battery holder the system shuts o the re
completely. This does not apply when the power supply
is interrupted.
On-Demand Pilot.
This green feature eliminates
gas energy consumption during extended appliance
inactivity. When the appliance is inactive for 5 days
the system automatically extinguishes the pilot. This
feature helps the consumer realize cost bene ts by
automatically eliminating energy consumption during
non-heating months and limited use.
Using the Remote Control
to save them.
8:00 am
End time
P1
Set temp
40 F
4:00 pm
Start time
P2
Set temp
74 F
Low Battery Indication
Caution
DO NOT USE a screwdriver or other metallic
object to remove batteries from holder. This
could cause a short-circuit.
Handset:
The battery icon
tery needs to be replaced. Replace with one 9 V alkaline
battery.
Battery holder:
Frequent 'beeps' for 3 seconds when
the valve motor turns indicate the batteries need to be
replaced in battery holder. Replace with four 1.5 V alka-
line batteries.
Handset / Receiver Match
The remote control handset and receiver are
programmed to function together. In case of a
replacement of the handset or the receiver, you will
need to reset the receiver to allow them to function
together. Contact your dealer for details.