Specifications
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
6
2100PKN 2100PKP
Natural
Propane
0-4,500 feet*
25,000
25,000
14,000
14,000
3.5"
10"
5"
11"
10"
14"
42
53
51
30
185
125
Supply Gas
Heater engine 2100PKN is used with natural gas.
Heater engine 2100PKP is used with propane gas.
The supply pressure must be between the limits
shown in the Ratings section.
The supply connection is 1/2" NPT male and located
on the wall end of the fi rebox. See page 31.
A shutoff valve is supplied on the supply line to isolate
the unit during service. See Connect Gas Supply section
for details.
Electrical
The 2100P is designed to run on battery power and
does not require an electrical source to operate
as a heater. However, it requires electrical power
to operate the overhead lighting, the WiFi module
(optional), or 1270RBK Remote Blower Kit (optional)
Conversion Kits
The 2100P is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kits for further
information.
 WARNING
A HeatShift kit is required with this
fireplace.
Note: This appliance is designed and approved as
a supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.
Gas shutoff
location