QUALIFIED
INSTALLER
Approvals and Codes
This appliance is certifi ed to ANSI Z21.88–2016/CSA
2.33–2016 American National Standard/CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA.
The appliance complies with CSA P.4.1-15, Testing
method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223/NFPA 54.1or the Natural Gas and
Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install the
appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Model
Gas
Altitude (ft)*
Input max. (Btu/h)
Input min. (Btu/h)
Manifold pressure (in w.c.)
Min. supply pressure (in w.c.)
Max. supply pressure (in w.c.)
Main burner injector (no.)
Pilot injector (no)
Min. by-pass screw
*Tested to CGA - 2.17-91 Gas fi red appliances for use
at high altitudes. In USA, installations may require
deration over 2000' —Check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 530IN is used for natural gas installations.
Heater engine 530IP is used for propane gas installations.
20
Specifi cations
IN
IP
natural
propane
0-4 500 pieds*
20,500
19,000
6,500
12,500
3.5–3.9
10.3–10.7
5
11
10.5
14
580
200
35
27
125
125
The supply pressure must be between the limits shown
in the Ratings table on the previous page.
The supply connection is 3/8 inch NPT female located at
the left side of the control valve. The opening for the gas
supply line is at the rear left corner of the appliance.
Gas line access
at rear left
corner
Gas supply
connection 3/8"
NPT female at
valve
Fuel Beds
The 530 engine is available in either natural gas or
propane gas can use a simulated logs, coals, rocks or
driftwood fuel bed in either fuel.
Electrical
The unit does not require an electrical power source
unless fi tted with an optional circulating fan.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft fl ooring require sheet metal extending
the whole width and depth under the appliance. This
appliance does not require a hearth. Combustible
fl ooring may extend up to the front of the unit.
Front Trims/Stove
Various fronts are available for the 530 engine. This
engine may be installed as a free standing, zero
clearance or insert application depending on which
style front trim is selected. The front trim/stove
style aff ects the framing cavity, clearances and
position of the engine. A front trim kit is required
for all applications and should be on site when
the engine is installed as the parts to make the
engine suitable for zero clearance are supplied with the
front trim kits (except 549 front).
Outdoor Conversion Kit
The 530IN/IP ZC model is supplied standard for indoor
applications and may be adapted for installation in
specifi c "outdoor" applications protected from weather as
defi ned in the GV60CKO outdoor conversion kit manual.
WARNING
!
O p t i o n a l e l e c t r i c a l a c c e s s o r i e s
A R E N O T A L L O W E D w h e n a d a p t i n g
a p p l i a n c e f o r o u t d o o r u s e .
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.