3.1 Copy Count Meter RAP
This RAP is used for a copy count meter fault
that does not indicate a status code.
Ensure that the Country Configuration (ADJ
3.3)
is
adjusted correctly before performing
this RAP.
Set the meter to measure
+
24 VDC.
Connect
(
+
)
t o P12-2 of the Control PWB;
(-)
to the GND test point on the HVPS.
Enter the diagnostic mode.
Enter the code
[20]
for the copy count meter.
The voltage goes from
+
24 VDC to less than
+
1 VDC.
Y
N
I
Replace the Control PWB.
Replace the copy count meter.
If the oroblem still exists. reolace the Control
PWB.
I
/
CONTROL PWB
I
M 1
COPY COUNT
COUNTTHE
METER
COPY (L)
+
24
PL
1.4
!
PI2
"DC
I
I
BLK
I
I
I
I
12/98
3.1 Copy Count Meter RAP
2-62
3001