Xerox 3001 Service Manual page 220

Engineering copier 60/50 hz
Table of Contents

Advertisement

(Continued)
REPLACEMENT
1. (FIGURE 2): INSTALL THE HEAT ROD.
STEP 1 C: Oil from your fingers can
damage the heat rod. Wear gloves or
wrap a sheet of paper around the heat
rod when handling the heat rod.
STEP 1 C: lnstall the Heat Rod, white
connector first.
DO NOT
remove the
connectors from the wires on the ends
of the heat rod. The heating element
inside the rod is closer to the end with
the white connector.
Q
STEP
1 F:
When reinstalling the (2)
screws, ensure that the head of the
screws fit into the hole in the Fuser
Roll.
WARNING
There will be a time delay between the time
the code [lo] is entered and the time the
motor starts to turn. The motor will not
start until
the fuser is at the correct
temperature.
Q
Enter diagnostic mode. Enter the
code [lo] and allow the copier to run
for
15
minutes to allow the fuser oil to
condition the fuser roll.
Q
Ensure that the Thermistor is clean
and touches the fuser roll after
assembly.
D
GUIDE WHITE
VE
E R
REINSTALL
ONE EACH
THE
ROLL
Figure 2. Install the Heat Rod
(Continued)
12/98
REP 10.1
4-40
3001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents