Adj ? 1 Timeout Interval T O; Rest Mode; Adj 3.2 Timeout Interval T O Power Saver Mode; Adj 3.3 Country Configuration - Xerox 3001 Service Manual

Engineering copier 60/50 hz
Table of Contents

Advertisement

ADJ 3.1 TIMEOUT INTERVAL TO
REST MODE
Purpose
The purpose is t o set the amount of time it
takes the copier t o return t o the Power
Saver from the Power Saver Mode.
lntroduction
The timeout interval should be set t o the
requirements of the customer. The time is
preset by manufacturing for 25 minutes. The
time interval can be set from 5 minutes t o 45
minutes.
Adjust
1. ENTER THE DIAGNOSTIC MODE.
2. USING THE ARROW BUTTONS, ENTER THE
CODE [8]. PRESS THE Start BUTTON.
Q
lncreasing the value displayed will
increase the timeout interval. One
number will increase or decrease the
interval b y 15 minutes.
3.
USE THE
/\
BUTTON IN ORDER TO
INCREASE OR THE
\/
BUTTON IN
ORDER TO DECREASE THE VALUE
DISPLAYED ON THE CONTROL PANEL.
4. PRESS THE Start BUTTON TO STORE NEW
SETTING.
5.
EXlT THE DIAGNOSTIC MODE.
ADJ 3.2 TIMEOUT INTERVAL TO
POWER SAVER MODE
-
(USO), ( A 0 60 Hz);
LOW POWER MODE
-
(EO), ( A 0 50 Hz)
Purpose
The purpose is t o set the amount of time
it
takes the copier t o return t o the Power
Saver Mode from the Run Mode.
lntroduction
The timeout interval should be set t o the
requirements of the customer. The time is
preset by manufacturing for 1 minute. The
time interval can be set from 45 seconds t o
3
112 minutes.
Adjust
1. ENTER THE DIAGNOSTIC MODE.
2.
USING THE
+
OR
-
BUTTONS, ENTERTHE
CODE [I]. PRESS THE Start BUTTON.
Q
lncreasing the value displayed will
increase the run time interval after
the last copy was made. One number
will increase o r decrease the interval
by 15 seconds.
3.
USE THE/\
BUTTON IN ORDERTO
INCREASE OR THE
BUTTON IN
ORDER TO DECREASE THE VALUE
DISPLAYED ON THE CONTROL PANEL.
4.
PRESS THE Start TO STORE NEW SETTING.
5.
EXlT THE DIAGNOSTIC MODE.
ADJ 3.3 COUNTRY
CONFIGURATION
Purpose
The purpose of this procedure is t o set up the
correct Country Configuration for the copier.
Adjust
1. ENTER THE DIAGNOSTIC MODE.
2.
USING THE/\
OR\-J
BUTTONS,
ENTER THE CODE [9]. PRESS THE Start
BUTTON.
3.
USING THE
+
OR
-
BUTTONS, SELECT THE
APPROPRIATE CONFIGURATION CODE,
AND PRESS THE Start BUTTON TO STORE
THE NEW CONFIGURATION VALUE.
Code
Configuration
4.
EXlT THE DIAGNOSTIC MODE.
12/98
3001
4-59
ADJ 3.1, ADJ 3.2, ADJ 3.3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents