Esc $ Nl Nh Set Absolute Horizontal Print Position; Esc D N1 - SNBC BTP-R580II Programming Manual

Table of Contents

Advertisement

09 (the same as above)
33 33 33 33
09 (the same as above)
33 33 33 33
0A (print)
33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33
33
0A (print)
Result:

ESC $ nL nH Set absolute horizontal print position

[Function]
The distance from the beginning of the line to the current position is (nL +
nH×256)×(vertical or horizontal motion unit).
[Format]
ASCII
Hex
Decimal 27
[Range]
0≤nL≤255
0≤nH≤255
[Notes]
• Settings outside the specified print area are ignored.
• The horizontal and vertical motion units are specified by GS P.
• In standard mode, the horizontal motion unit (x) is used.
• In page mode, this command functions as follows, depending on the direction and
print starting position of the print area:
① When the starting position is set to the upper left or lower right of the print area by
② When the starting position is set to the upper right or lower left of the print area by
[Relative]
ESC \, GS $, GS \, GS P
[Example]
Refer to ESC W.
ESC D n1...nk NUL Set horizontal tab positions
[Function]
• Set horizontal tab positions.
• Set a tab position at the nth column from the beginning of the line.
• There are k tab positions in all.
[Format]
ASCII
Hex
Decimal 27
ESC
$
nL nH
1B
24
nL nH
36
nL nH
ESC T, the horizontal motion unit (x) is used;
ESC T, the vertical motion unit (y) is used.
ESC
D
n1 nk
1B
44
n1 nk
68
n1 nk
BTP-R580II Programming Manual
NUL
00
0
- 6 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents