8. Adjust the tip cleaning assembly until the brush just
touches the tips but just misses the bottom of the tip
shroud (see
Top of brush
just misses
flat portion of
tip.
Figure 16: Replacing the tip cleaning brush
As Needed Maintenance
The following maintenance items have no routine schedule but
should be tended to as needed.
Chamber Lamp
Replace the chamber lamp when it burns out.
To replace the chamber lamp:
1. Power down the system.
2. Locate the lamp socket plug about 3 inches beneath the
lamp socket. Unplug lamp socket from wire harness.
3. Lightly pull the socket wires away from the socket while
pulling lamp straight out of the socket.
Figure
16) and tighten mounting screws.
Bottom of nipples
must hit brush
and top half of
exposed flicker.
Maintenance 47
Mounting Screws
Prodigy Plus User Guide