56 Troubleshooting
Recovering From Loss of Extrusion
Before proceeding, read through the entire procedure.
Overview
1. Enter Maintenance mode.
2. Attempt to re-establish extrusion.
3. Snip both filaments approximately 1 inch from the fixed
part of the head.
4. Remove the filament from both drive block assemblies
if there is enough to remove by hand.
5. Remove both drive block assemblies from the swivel
part of the head.
6. Inspect the drive block funnels for obstructions.
7. Inspect the liquefier inlets for material buildup.
8. Clean the inside of the liquefier inlets.
9. Replace both drive-block assemblies.
10. Clean the drive wheels.
11. Check for extrusion.
Prodigy Plus User Guide